Best Datex-Ohmeda OXY-F4-N Compatible Adult Finger Clip SpO2 Sensor Pulse Oximeter

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Guangdong
Validity to: Long-term effective
Last update: 2017-09-07 19:32
Browse the number: 478
inquiry
Company Profile
 
 
Product details

Best Datex-Ohmeda OXY-F4-N Compatible adult finger clip SpO2 Sensor pulse oximeter

This compatible sensor connects directly to the bedside monitor without an extension cable. It works with the following patient monitors: Datex-Ohmeda : Aespire, Aespire 15, AS/3, AS/3 Compact, CS/3, S/5, S/5 Compact, CH/S, CH/2S, CH-RS, CG/2S, Cardiocap I, Cardiocap II, Cardiocap 5, Capnomac Ultima, Light Monitor, M-NESTPR, Oscar II, OSP-200, Satellite Trans, Satellite, Satellite Plus II, Trans Plus, System 5, ULTS00, OXY-E4-N, ULTSIO, ULTSVI, ULTSVO. 9-foot cable. Compatible sensors are available for the following Datex-Ohmeda

OEM part numbers:

· OXY-F4-N (Adult Clip)

· TS-F4-N (Adult Clip)

· SAF-F4 (Adult Clip)

· OXY-W4-N (Neonate Silicon Wrap)

· OXY-E4-N (Adult Ear Clip)

· TS-E4-N (Adult Ear Clip)

Specifications

· Datex ohmeda Adult spo2 sensor
· Latex free
· 3m TPU cable
· one year warranty
· High performance/price ratio for Reusable SpO2 sensor to save cost
· Easy to clean and repair
· Finger clip, Soft tip, Wrap, Multi-Y, Ear clip types available
· Available in adult, pediatric, infant and neonate sizes
· Different types are Compatible with most of patient monitors

· Safety: IEC 60601-1-1 approved, conformity with MDD 93/42/EEC and EN9919:2005

· Patient sizes: Pediatric

· Ambient temperature: 0 to 40°C(32 to 104°F)

· Relative humidity: 15% to 95%

· Measurement technology: Tri-wavelength LEDs & photo detector

· LED wavelength: 660nm/880nm/940nm

· SpO2 accuracy: ±3 (70-100%); Unspecified (0-69%)

· Pulse rate range: 20-250bpm

· Pulse rate accuracy: ±3 (20-250bpm)

· Packages: non-sterilization, individual package with instruction

Main technical parameters

Emitting light waven length

660±5nm

Absorbed light wavelength

905±5nm or 940±5nm

SpO2 testing range

70%-100%

SpO2 testing precision

±1% in 90%~100%

±2% in 80%~89%

±3% in 70%~79%

Testing range of pulse velocity

30bpm~245bpm

Testing precision of pulse velocity

30bpm~59bpm,±1bpm

60bpm~149bpm,±2bpm

150bpm~245bpm,±3bpm

Working environment requirements

Environment temperature

5°C~40°C

Relative humidity

≤80%

Atmospheric pressure

700hPa~1060hPa

We are a professinal manufacturer in mainland China,we have various brands of below item:
spo2 sensor,
ECG cable and leadwire,
EKG cable and leadwire,
IBP cable,
NIBP cuff & tubes ,
temperature probe,
holter cable and leadwire,etc.
EEG electrodes
Ecg Electrodes
Infusion cuff
Water trap
Heater wire cable


Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]