LP72-182 series silicon solar module products insists of 72 pieces half-cut Monocrystalline solar cells, and its power output can be up to 530W/535W/540W/545W/550W. Moreover, its double glass structure which enhance the reliability of anti-microcracks and reduce the snail tracks phenomenon. Its module efficiency can be 20.9%. With its advantages, it is usually used in Asia and Africa market.


Specification.


Engineering Drawing



Electrical Charateristricts

Module

LP72-182

Maximum Power at STC(Pmax)

530W

535W

540W

545W

550W

Open-Circuit Voltage(Voc)

49V

49.2V

49.4V

49.6V

49.8V

Short-Circuit Current(Isc)

13.76A

13.81A

13.87A

13.93A

13.99A

Optimum Operating Voltage (Vmp)

40.80V

41V

41.2V

41.4V

41.6V

Optimum Operating Current(Imp)

13.00A

13.05A

13.11A

13.17A

13.23A

Module Efficiency

20.51%

20.70%

20.90%

21.09%

21.28%

Power Tolerance

0 ~ +5W





Maximum System Voltage

1000V / 1500V DC(IEC)

Maximum Series Fuse Rating

25A





Operating Temperature

-40 °C to + 85 °C





*STC:Irradiance 1000W/m2,module temperature 25, AM=1.5

Optional black frame or white frame module according to customer requirements


NOCT

Module

LP72-182





Maximum Power

395W

399W

402W

406W

410W

Open Circuit Voltage (Voc)

45.9V

46.1V

46.3V

46.4V

46.6V

Short Circuit Current (Isc)

11.09A

11.13A

11.18A

11.23A

11.28A

Maximum Power Voltage (Vmp)

38.0V

38.2V

38.4V

38.6V

38.8V

Maximum Circuit Current (Imp)

10.40A

10.44A

10.49A

10.54A

10.58A

NOCT

45°C±2°C





*NOCT:Irradiance 800W/m2,ambient temperature 20°C,wind speed 1 m/s


I-V Curves

Mechanical Characteristics

Solar Cells

Monocrystalline 182 × 182mm

No.of Cells

72 (6 × 24)

Dimensions

2279mm*1134mm*35mm

Weight

29kg

Front Glass

High transmission tempered glass

Frame

Aluminum Alloy

Junction Box

IP68

Cable

4mm2, Landscape: N 1400mm/P 1400mm

Portrait: N 200mm/P 300mm

Packaging Configuration

31pcs/pallet, 620pcs/40' Container


Temperature Characteristics

Temperature Coefficient of Pmax

γ (Pm)

-0.39%/K

Temperature Coefficient of Voc

β (Voc)

-0.29%/K

Temperature Coefficient of Isc

α (Isc)

0.049%/K



Warranty.



10-year product warranty

30-year warranty on power output


Specific information is referred to the product quality guarantee


Details Images.



Silicon Photovoltaic Cell


High efficiency 9BB PV cell

Uniform color

Anti-PID

Germany standard Cell

Full test


Junction box


Conventional standalone edition and engineering custom edition

Quality diode ensures module running safety

IP68 protection level

Heat dissipation

Long service life





Glass


Antireflective glass

Translucency of normal luminance is increased 2%

Module efficiency is increased 2%

Self-clean function

Service life 25 years

Frame


Stock-size

Silvery and black

Thickness 30/35/40/50mm

Stress test




Application.


Industrial Roof

PV Power Station


Distributed Power Station

Household Roof



Quality Control.



Certification.



Production Line.



Exhibition.



Q&A.


1.How to determine the installation orientation of PV arrays? What is the effect on power generation?


Since the main reason that affects the photovoltaic power generation is the amount of sunshine, the modules should be installed in the direction with the most sunlight. Different installation angles also have an impact on the power generation of photovoltaic modules.


2.How to estimate the power generation of distributed photovoltaic grid-connected system?

To estimate the generation capacity of a photovoltaic power generation system, it is necessary to know the effective sunshine time, system efficiency and system installation capacity of the place where the system is installed. You can also consult with the installation of photovoltaic systems to get more accurate power generation.


3.What information should be provided by the customer when the design engineer designs the system according to the customer's requirements?

When the system is designed, the information that needs to be provided by the customer is divided into options and strong options.

Required options include installation location, building environment, year of construction, roof type, roof load, access voltage level and roof photos.

The optional parts include average monthly electricity consumption, roof panel structure, CAD drawings, roof surface conditions, electricity meter box photos, etc. Of course, the more detailed the optional parts are, the more conducive to optimize the design in a more reasonable way and improve the power generation.





http://www.solalifetrade.com/

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]